[BATTERY SETTING]
Item
[BATTERY MODE]
Selects whether to set the near end voltage of a battery.
[AUTO]
[MANUAL]
[HYTRON140 NEAR
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
END]
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [HYTRON140].
[12.0V]...[13.1V]...[15.0V]
[DIONIC 90 NEAR
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
END]
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [DIONIC90].
[12.0V]...[13.7V]...[15.0V]
[ENDURA10 NEAR
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
END]
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [ENDURA10].
[12.0V]...[13.4V]...[15.0V]
[PAG L96e NEAR
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
END]
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [PAG L96e].
[12.0V]...[13.0V]...[15.0V]
[TYPE A FULL]
Selects the voltage for full display in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE A].
[13.0V]...[15.6V]...[17.0V]
[TYPE A NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE A].
[11.0V]...[13.2V]...[15.0V]
[TYPE A END]
Selects the end voltage in steps of 0.1 V when the main menu → [I/F SETUP] →
[BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE A].
[11.0V]...[12.5V]...[15.0V]
[TYPE B FULL]
Selects the voltage for full display in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE B].
[13.0V]...[15.9V]...[17.0V]
[TYPE B NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE B].
[11.0V]...[12.9V]...[15.0V]
[TYPE B END]
Selects the end voltage in steps of 0.1 V when the main menu → [I/F SETUP] →
[BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE B].
[11.0V]...[12.5V]...[15.0V]
[TYPE C FULL]
Selects the voltage for full display in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE C].
[13.0V]...[15.9V]...[17.0V]
[TYPE C NEAR END]
Selects the near end voltage in steps of 0.1 V when the main menu → [I/F
SETUP] → [BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE C].
[11.0V]...[13.2V]...[15.0V]
[TYPE C END]
Selects the end voltage in steps of 0.1 V when the main menu → [I/F SETUP] →
[BATTERY/P2CARD] → [BATTERY SELECT] is set to [TYPE C].
[11.0V]...[12.5V]...[15.0V]
[BATT STAT NEAR
Selects the near end percent value.
END]
[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
[BATT STAT END]
Selects the end percent value.
[1%]...[10%]
[ENDURA STAT
Selects the near end percent value.
NEAR END]
[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
[ENDURA STAT END]
Selects the end percent value.
[1%]...[10%]
Chapter 7 Menu Operations — Menu list
Description of settings
Automatically set.
Manually set.
– 173 –
Remark
f This item is enabled when [BATTERY MODE] is
set to [MANUAL].
f This item is enabled when [BATTERY MODE] is
set to [MANUAL].
f This item is enabled when [BATTERY MODE] is
set to [MANUAL].
f This item is enabled when [BATTERY MODE] is
set to [MANUAL].
The [TYPE A] factory setting corresponds to the IDX
ENDURA ELETE.
The [TYPE B] factory setting corresponds to the
Anton/Bauer DIONIC HC.
f When the battery charge level percentage cannot
be detected, this will follow the near end voltage
value set in [TYPE A].
f If a battery is used for which the remaining charge
is displayed in units of 10%, the setting value and
actual near end warning may vary slightly.
f When the battery charge level percentage cannot
be detected, this will follow the end voltage value
set in [TYPE A].
f When using a battery which displays battery
charge level by units of 10%, end is determined
only in two stages: when it is set between [1%]
and [5%], or when it is set between [6%] to [10%].
f When the battery charge level percentage cannot
be detected, this will follow the near end voltage
value set in [TYPE A].
f If a battery is used for which the remaining charge
is displayed in units of 10%, the setting value and
actual near end warning may vary slightly.
f When the battery charge level percentage cannot
be detected, this will follow the end voltage value
set in [TYPE A].
f When using a battery which displays battery
charge level by units of 10%, end is determined
only in two stages: when it is set between [1%]
and [5%], or when it is set between [6%] to [10%].
are factory settings.