Panasonic AJ-PX5000G Operating Instructions Manual page 172

Hide thumbs Also See for AJ-PX5000G:
Table of Contents

Advertisement

Item
[VF/LCD CHAR]
Selects whether to display a character on the image of the LCD monitor and
viewfinder.
[ON]
[VF-OFF]
[LCD-OFF]
[BATTERY/P2CARD]
Item
[BATTERY SELECT]
Selects the battery to use.
[HYTRON140]
[DIONIC90]
[ENDURA10]
[PAG L96e]
[TYPE A]
[TYPE B]
[TYPE C]
[BATT STAT]
[ENDURA
STAT]
[EXT DC IN SELECT]
Sets the type of charge level to connect a battery to the <DC IN> terminal. Also
detects a charge level that corresponds to the selected type.
Information about selecting a battery type is the same as [BATTERY SELECT].
Displays the analog voltage on the viewfinder screen.
[DC PWR SUPPLY], [HYTRON140], [DIONIC90], [ENDURA10], [PAG L96e],
[TYPE A], [TYPE B], [TYPE C]
[BATT NEAR END
Selects whether to play the warning sound at battery near end.
ALARM]
[ON], [OFF]
[BATT NEAR END
If set to [ON], the warning sound and warning display output can be canceled
CANCEL]
when the <MARKER SEL>/<MODE CHECK/MENU CANCEL> switch is pushed
towards the <MCK/MCL> side at battery near end.
[ON], [OFF]
[BATT END ALARM]
Sets whether to output the warning sound at battery near end.
[ON], [OFF]
[BATT REMAIN FULL] Sets the content of the battery remaining charge bar of the display window when a
battery with charge level display function is used.
[70%]
[100%]
[CARD NEAR END
Sets whether to output the warning sound at P2 card near end.
ALARM]
[ON], [OFF]
[CARD NEAR END
Sets remaining time to emit the P2 card near end warning.
TIME]
[2min], [3min]
[CARD END ALARM]
Sets whether to output the warning sound at P2 card end.
[ON], [OFF]
[CARD REMAIN/Seg]
Sets the time of one segment (r) for the P2 card remaining capacity bar in the
display window.
[3min/Seg]
[5min/Seg]
Chapter 7 Menu Operations — Menu list
Description of settings
Displays a character on both the viewfinder and LCD monitor.
Does not superimpose on the viewfinder, and displays on the
LCD monitor.
Does not superimpose on the LCD monitor, and displays on the
viewfinder.
Description of settings
Detects the battery charge level according to the selected
battery when the Anton/Bauer HYTRON140 or DIONIC90, the
IDX ENDURA10 (E-10), and the PAG PAG L96e are selected.
Select any item when a battery other than [HYTRON140],
[DIONIC90], [ENDURA10], or [PAG L96e] is used. At this
time, set [FULL] (full voltage), [NEAR END] (near end warning
voltage), and [END] (end voltage) in the main menu → [I/F
SETUP] → [BATTERY SETTING] (page 173) according to the
battery in use.
When using a battery whose charge level is detected as a
percentage value, near end and end operation is conducted
according to the percentage value of the charge level if
[BATT STAT] is selected. Set the percentage value of [BATT
STAT NEAR END] (near end) and [BATT STAT END] (end)
in the main menu → [I/F SETUP] → [BATTERY SETTING]
(page 173) according to the battery in use.
Select when IDX ENDURA battery is used to operate at near
end and end according to the percentage value of the charge
level information. Set the percentage value of [ENDURA STAT
NEAR END] (near end) and [ENDURA STAT END] (end)
in the main menu → [I/F SETUP] → [BATTERY SETTING]
(page 173) according to the battery in use.
Fully displays at 70%.
Fully displays at 100%.
One segment is three minutes
One segment is five minutes
– 172 –
Remark
f This item can be set in the main menu → [VF] →
[VF DISPLAY] as well.
are factory settings.
Remark
f When the battery charge level percentage
cannot be detected, it will follow the setting value
of [TYPE A] even if it is set to [BATT STAT] or
[ENDURA STAT]. Make sure that the [TYPE A]
setting values [FULL] (fully charged), [NEAR END]
(near end), or [END] (end) is appropriate for the
battery being used.
are factory settings.

Advertisement

Table of Contents
loading

Table of Contents