UNIVERGE SV8100
Input Data
Item
Programming Manual
No.
12
Number of G.723 Audio Frames
13
G.723 Voice Activity Detection Mode
14
G.723 Jitter Buffer Min
15
G.723 Jitter Buffer Average
16
G.723 Jitter Buffer Max
17
Jitter Buffer Mode
18
Voice Activity Detection Threshold
19
Idle Noise Level
20
Echo Canceller Mode
21
Echo Canceller Tail Size
22
Echo Canceller NLP Mode
24
Echo Canceller CNG Configuration
Item
Input Data
1~2
1 = 30ms
2 = 60ms
0 = Disable
1 = Enable
0~270ms
0~270ms
0~270ms
1 = Static
2 = Adaptive during
silence
3 = Adaptive immediate
0~30 (-19db~ +10db)
0 = Self adjustment
1 = -19db (-49dbm)
:
20 = 0db (-30dbm)
:
29 = 9db (-21dbm)
30 = 10db (-20dbm)
5000~7000
(-5000dbm~ -7000dbm)
0 = Disable
1 = Enable
1 = 4ms
2 = 8ms
3 = 16ms
4 = 32ms
5 = 64ms
6 = 128ms
0 = Disable
1 = Enable
0 = Adaptive
1 = Fixed
Issue 1.0
Default
1
0
30
60
120
3
20
7000
1
6
1
0
2 - 685