Program 35 : Smdr Account Code Setup; Smdr Options - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Program 35 : SMDR Account Code Setup

Level:
IN
Description
Use Program 35-01 : SMDR Options to set the SMDR (Station Message
Detail Recording) options for each of the eight SMDR ports. Refer to the
following chart for a description of each option, its range and default setting.
Input Data
Item
No.
01
02
03
04
05
Programming Manual
SMDR Port Number
Item
Output Port Type
This option specifies the type of
connection used for SMDR. The baud rate
for the COM port should be set in Program
10-21-02 or 15-02-19.
Output Destination Number
This option specifies the SMDR printer
output extension (CTA/CTU extension
number).
Header Language
Specify the language in which the SMDR
header should be printed.
Omit Digits
The number of digits entered in this option
do not print on the SMDR report. For
example, if the entry is 10, the first 10
digits a user dials do not appear on the
SMDR report.
Minimum Digits
Outgoing calls must be at least this
number of digits for inclusion in the SMDR
report.

35-01 : SMDR Options

1~8
Input Data
0 = None
3 = LAN
4 = CTA/CTU
Up to 8 digits
0
= English
1
= German
2
= French
3
= Italian
4
= Spanish
0~24 (0 = Not applied)
0~24 (0 = Not applied)
Program
35
Default
0
No
Setting
0
0
0
2 - 405

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents