UNIVERGE SV8100
Alarm
Type
Report
No.
61
0
0
SIP extension
trouble
information.
62
0
0
DtermIP
trouble
information.
63
0
0
SIP-MLT
trouble
information.
64
1
0
VoIPDB LAN
Link Error.
65
0
0
VoIPDB
trouble
information.
66
2
0
SIP extension
License Error.
67~79
--- Reserved ---
80
1
0
NetLink start
error.
Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
It failed in the registration
of the SIP extension
terminal.
The SIP extension terminal
was not able to acquire
DSP.
• At Regist to SV8100 of
the SIP extension terminal.
• When you cannot acquire
the DSP resource when it
sends it.
The error occurred by the
DtermIP relation.
• When the error occurs
while communicating with
VoIPU or DtermIP.
• When it becomes
impossible to do the
communication between
SV8100 and DtermIP
• When failing in the
acquisition of DSP.
The trouble occurred by
the SIP-MLT relation.
• The DSP resource was
not able to be acquired at
incoming/outgoing.
• The negotiation with
VoIPDB failed.
The link of LAN of VoIPDB
came off.
When DSP of VoIPDB
notifies Error.
More than the number of
licenses to which the SIP
extension terminal was
turned on at REGISTER.
The error occurred when
NetLink started.
Cause
Action
• The registered
Reconfirm wiring and
port is used by
the system data setting.
other extension.
• The license is
Confirm whether each
insufficient.
equipment such as
• DSP of VoIPDB
access points works
was not able to be
normally.
acquired.
• The packet loss
Confirm whether each
occurred on the
equipment such as
network or the
wirings and HUB is
wiring cutting
normal.
occurred.
• DSP of VoIP was
not able to be
acquired.
• The packet loss
Confirm whether each
occurred on the
equipment such as
network or the
wirings and HUB is
wiring cutting
normal.
occurred.
• DSP of VoIP was
not able to be
acquired.
• LAN cable is
Confirm LAN connector
defective.
and wiring.
• Connected HUB
Please inquire an
broke.
uncertain point of the
maker.
• Defect in
CD-CP00-US.
• Defect of
There is a defective
PZ-32IPLA.
possibility of hardware.
Please inquire an
uncertain point of the
maker.
• Lack of number of
Confirm the number of
licenses.
licenses of SIP
extension terminals.
Please inquire an
uncertain point of the
maker.
•Defect on
There is a defective
CD-CP00-US.
possibility of hardware.
Please inquire of the
maker.
Issue 1.0
Alarm
Recovery
Status
ERR
REC
ERR
REC
WAR
When the
ERR
REC
connection
returns
normally, the
error is
recovered.
WAR
When the
WAR
number of
registration of
SIP extension
terminals falls
below the
number of
licenses.
ERR
2 - 711

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents