UNIVERGE SV8100
Alarm
Type
Report
No.
6
0
0
Blocking
7
1
0
Power failure
8
1
0
RAM Backup
Battery Error
9
--- Reserved ---
10
0
0
ISDN Link
Error
11
0
0
CTI Link Error
12
0
0
ACD MIS Link
Error
Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The link of terminals
connected with the ESI
package came off.
The supply of the
commercial power
stopped.
RAM backup battery on the
CD-CP00-US blade is
unplugged or defective.
Layer1 link of ISDN lines
came off.
The link with the CTI server
came off.
The link with ACD MIS
client PC came off.
Cause
Action
• Breakdown of
Confirm the terminal
terminal.
connected with same
• Faulty wiring and
ESI. If they work
wiring
normally, confirm the
determination.
breakdown or the wiring
• External noise.
for the terminal.
• Breakdown of ESI
Exchange the terminal
package.
that doesn't work and
the working terminal,
and confirm it's
working. An external
factor of the noise etc.
is thought.
Please reconfirm wiring
and the installation,etc.
Please inquire of the
manufacturer when the
problem occurs after it
confirms it.
• The power cable
Confirm the power
came off.
supply outlet when the
• Power failure
commercial power has
• The power supply
not stopped.
unit broke down.
Please inquire of the
manufacturer when the
problem occurs.
Check the battery
connector. If it is
connected correctly,
replace the battery.
• Connected
Confirm the data of
determination of
PRG10-03.
main device and
Reconfirm wiring and
ISDN line
the installation of DSU.
• Breakdown of
Please inquire of the
DSU
manufacturer when the
• The setting of
problem occurs after it
PRG10-03 is not
confirms it.
corresponding to
an actual line.
• LAN cable
Please reconfirm the
defective.
CTI server, wiring, and
• Connected HUB
the connection.
broken.
Please inquire of the
• The CTI server
manufacturer when the
doesn't start
problem occurs after it
normally.
confirms it.
• LAN cable
Please confirm ACD
defective.
MIS client PC and
• Connected HUB
connected part.
broken.
Please inquire of the
• The CTI server
manufacturer when the
doesn't start
problem occurs after it
normally.
confirms it.
Issue 1.0
Alarm
Recovery
Status
The error is
ERR
recovered
REC
when
reconnecting
or exchanging
it.
When the
ERR
commercial
REC
power is
restored, the
error is
recovered.
The error is
ERR
recovered
REC
once the
battery is
replaced.
When the
ERR
connection
REC
returns
normally, the
error is
recover.
When the
ERR
connection
REC
returns
normally, the
error is
recover.
When the
ERR
connection
REC
returns
normally, the
error is
recover.
2 - 707

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents