Item
Item
No.
04
Hunting Mode
Use this option to set the action
taken when a call reaches the
last extension in the Department
Group (0=hunting stopped,
1 =hunting repeats with circular
routing through the Department
Group).
05
Extension Group All Ring
Mode Operation
Determine whether calls ringing
a Department Group should ring
all extensions in the group
simultaneously automatically or
manually when using the
service code defined in Program
11-12-09.
When set to (1)
Automatic, only ICM
Calls and DID Calls will
ring all the stations in the
Department Group.
06
STG Withdraw Mode
07
Call Recall Restriction for
STG
Determine whether or not an
unanswered call transferred to a
Department Group should recall
the extension from which it was
transferred.
08
--- Not Used ---
09
Department Hunting No
Answer Time
Set how long a call rings a
Department group extension
before hunting occurs.
10
Enhanced Hunt Type
Set the type of hunting for each
Extension (Department) Group.
Input Data
0
= Last extension is
called and hunting
is stopped
1
= Circular
0
= Manual
1
= Automatic
0
= Disable (Camp
On)
1
= Enable (Overflow
Mode)
0
= Disable (Recall)
1
= Enable (No
Recall)
0~64800 seconds
0
= No queuing
1
= Hunting When
Busy
2
= Hunting When
Not Answered
3
= Hunting When
Busy or No
Answer
Program 16 : Department Group Setup
UNIVERGE SV8100
Related
Default
Program
0
0
11-16-10
0
0
15
0