REP 10.4 Upper Option Harness
Parts List on
PL 10.30 Item 24
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Remove the Duplex Unit,
REP
10.1.
2.
Remove the Waste Toner Cartridge.
3.
Remove the Left Cover,
REP
28.3.
4.
Remove the Right Cover,
REP
28.2.
5.
Remove the Top Cover,
REP
28.5.
6.
Disconnect CN14 from the MCU Board,
Figure 1 Disconnect CN14 from the MCU Board
7.
Remove 2 screws (plastic) that secure the connector to the chassis,
Revision - Xerox Internal Use Only
Phaser 4600/4620 Printer Service Manual
WARNING
Figure
1.
Figure 2 Remove the Upper Option Connector
5/2011
4-85
Repairs
REP 10.4