SCP 1 Initial Actions

Initial Actions are used to gather information on the machine performance
Start a service call with SCP 1 and end with SCP6 Final Actions.
Also refer to
SCP 7
Configurations and Options.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Do not work in a confined space. 1m (39 inches) space is needed for safe working.
NOTE: Ignore any references in this manual to options not installed on the machine.
1.
Take note of symptoms or error messages.
2.
Ask the operator to describe or demonstrate the problem.
3.
Make sure that:
a.
The power cord is connected to the wall outlet and to the machine.
b.
Paper is loaded correctly and all paper trays and covers are closed
c.
If installed, the USB cable or network connection is installed correctly.
4.
If available, check the machine service log book for any previous actions that may be rel-
evant to the call.
5.
If this is the first service call to this machine perform
go to
SCP 3
Normal Call Actions.
Service Call Procedures
SCP 1, SCP 2
WARNING
WARNING
SCP 2
First Call Actions, otherwise

SCP 2 First Call Actions

First Call Actions are used for the first service call.
Procedure
1.
Check the machine configuration with the customer, refer to
tions and Options. Check that all required hardware and software is installed and/or
enabled.
2.
Check that all the relevant machine settings are correctly entered, refer to
Administration Tools.
3.
If a fault is present, go to
SCP 3
SCP 6
Final Actions.
4.
Enter the machine details and the customer details in the service log.
5/2011
1-4
SCP 7
Machine Configura-
Normal Call Actions. If there is no fault present, go to
Revision - Xerox Internal Use Only
Phaser 4600/4620 Printer Service Manual
GP 4