Rep 12.2 Finisher Control Board - Xerox Phaser 4620 Service Manual

Hide thumbs Also See for Phaser 4620:
Table of Contents

Advertisement

Figure 1 Remove the left cover
Repairs
REP 12.1, REP 12.2

REP 12.2 Finisher Control Board

Parts List on
PL 12.15 Item 2
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Separate the Finisher from the printer,
2.
Remove the left cover,
REP
12.1.
3.
Disconnect all connections to the Control Board.
4.
Remove 5 screws (metal) that secure the board to the bracket,
Figure 1 Remove the Finisher Control Board
5/2011
4-128
WARNING
GP
14.
Figure
1.
Revision - Xerox Internal Use Only
Phaser 4600/4620 Printer Service Manual