Replacement
After installation of the Top Door to the Top Cover and before lacing the Control Panel harness,
position the Top Cover so the Top Door hangs in the open position. With the Top Door in the
open position, lace the Control Panel harness around the 2 Top Cover Hooks.
Figure 6 Lacing the Control Panel harness
Revision - Xerox Internal Use Only
Phaser 4600/4620 Printer Service Manual

REP 2.2 Control Panel Board

Parts List on
PL 2.10 Item 8
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Control Panel buttons are not captive to the Control Panel Board. During disassembly, use
care to avoid dropping buttons into the printer.
1.
Open the Top Door.
2.
Remove 7 screws (plastic) that secure the lower cover to the Control Panel Assembly,
Figure
1.
Figure 1 Remove the Control Panel Assembly lower cover
3.
Remove 7 screws (plastic) that secure the Control Panel Bard to the lower cover,