2. IB-585 updating program
IB-585 programs can be updated from the [DTE] port or the SD card of the IB-585
terminal unit.
Note) Even if the program is updated, no system set values will be cleared.
Furthermore, the [F11] "ALL Clear" needs not to be pressed.
*** Updating from the [DTE] port ***
The program folder is "uppg_eva2." This folder has saved the following files:
・ALOADER.bin
・IB585APL.BIN
・up585.bat
・uppg.exe
COM port number to be updated is set to "COM-1." If the COM port of the PC used for
program update is set to any number other than "1," open the "up585.bat," and then
rewrite the following data, and then clobber and save it:
uppg ALOADER.bin IB585APL.BIN 0 0 200 1 1:115200 0
Procedure)
1. Turn OFF the power of the IB-585 terminal unit.
2. Connect the serial port of the PC to the [DTE] port of the IB-585 terminal unit with
9-pin D-sub straight cable.
PC
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
COM Serial Port
(RS-232C)
DCD
1
RxD
2
TxD
3
DTR
4
GND
5
DSR
6
RTS
7
CTS
8
RI
9
9 pin D-sub
(female)
(male)
8-17
8.2 NBDP Terminal Updating Program
Specify a COM port number.
[DTE]
IB-583
1
N.C
2
TXD
3
RXD
4
5
GND
6
7
8
9
9 pin D-sub
(male)

Advertisement