Ensuring Connection Of Coaxial Cable; Ensuring Mounting Of Copper Grounding Band And Fastening Of Gland - Furuno FS-1575 Service Manual

Ssb radiotelephone
Hide thumbs Also See for FS-1575:
Table of Contents

Advertisement

4. Ensuring connection of coaxial cable

Ensure that the coaxial cable is securely fixed. Particularly to finish the coaxial cable
shield, bend back the shield once, and then fix the portion bent back with a larger
clamp.
Furthermore, tape the end of the shield that was bent back.

5. Ensuring mounting of copper grounding band and fastening of gland

Make the copper grounding band as short as possible. Conduct grounding work so as
not to fracture the band due to vibration, and ensure that screws fixing the band are
securely fastened.
Ensure that the cable gland is securely fastened. Furthermore, apply a coating of
silicone rubber to the clearance of the cable gland and the ground mounting plate and
screws.
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Since the welded parts of copper
band may be broken by swinging
of wind, shorten the copper band .
The copper band should be as
short as possible.
6-57
6.9 Checking Antenna Coupler

Advertisement