4.10 EXTERNAL ALM Output Setting (N.C, N.O)

When a DSC message is received, EXT ALM output (#7: H - #8: C of TB7) will be
activated. The EXT ALM output type can be set to "Normally Closed" or "Normally
Open." The factory set is "Normally closed."
Reference)
EXT ALM output (#7: H - #8: C of TB7):
When the ALM contact is closed, the output resistance is approximately 25
ohms (nonpolar). When it is open, the resistance is high.
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
1
4
3
4
3
2
Fig. 4.10.1 EXTERNAL ALARM I/F Circuit
4-91
4.10 EXTERNAL ALM Output Setting (N.C, N.O)
J8
TB7
3
2
1
J8:
1 − 2: Normally Open
2 − 3: Normally Closed