10. RX FIL board: 05P0862A, 05P0862B (FS-5075, -2575/-1575)

No setting is required.

11. MOT board: 05P0860 (FS-5075, -2575, -1575)

No setting is required.

12. T-CPU board: 05P0859 (FS-5075, -2575, -1575)

When a combination of programs installed to the T-CPU board is different from that of
programs installed to the C-CPU board of the FS-2575C unit, programs will be
automatically loaded from the T-CPU into the C-CPU.
1) Make system settings as listed in the table below.
Setting Item
MMSI setting (Must)
Registration of USER CH
Entry of POSITION
Selection of RX ANT
Availability of FAX RX
Selection of DSC CLASS
RT SETUP setting
TX POWER
IC-350 connection setting
2) Set the "S2" DIP switch all to "OFF."
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Menu
Set "S1" on the T-IF board to "ON," and then enter the
password.
[MENU] -> 2.USER CH
[MENU] -> 5.SYSTEM -> 4.POSITION
[MENU] -> 5.SYSTEM -> 7.RX SETUP -> 2.ANT SELECT
[MENU] -> 5.SYSTEM -> 7.RX SETUP -> 1.FAX RX
[MENU] -> 9.SERVICE -> 2.DSC SETUP -> CLASS
[MENU] -> 9.SERVICE -> 3.RT SETUP -> All Sub-menus
[MENU] -> 9.SERVICE -> 4.TX PWR (FREQ)
[MENU] -> 9.SERVICE -> 7.OTHER -> ALARM UNIT
DIP SW: S2
(ALL OFF)
6-71
6.10 Replacement of Boards