Introduction

When the FS-xx75 Series is installed, be sure to register MMSI. Not doing so will
disable DSC communications. Creating a DSC message or making a Distress call
without registering the MMSI will cause to display the following message and output an
alarm.
To make and receive a group call, a Group ID must be registered. Select [MENU] -> 6.
DSC -> 1. ADDRESS BOOK to register the Group ID.

1. Menus

Menu
Conducts DAILY TEST, TX SELF TEST, and other TX output
power check with TONE modulation. Be sure to provide user with
1. TEST
an explanation of handling of this operation.
Explain to the user that information on the TEST results helps the
user conduct troubleshooting in case of equipment failure.
2. USER CH
Registers USER CH for SSB, DSC, and NBDP frequencies.
3. LOG
Checks DSC communication LOG.
Select this menu to perform "Inter-comm." calls when two units of
4. INTERCOM
FS-2575C are connected.
This menu includes user setting submenus. Particular settings are
as follows:
• KEY ASSIGN setting: Provides a useful function that allows the
5. SYSTEM
• RX SETUP: Makes setting of this menu according to the
• NETWORK: Default setting is accepted. Making a setting
Makes DSC-related settings, including SCAN, ADD BOOK, and
MSG FILE registration.
6. DSC
Provide user with an explanation of the method for registering
station to make a test call and the handling of the station.
Makes alarm-related settings.
7. AUDIO
This menu includes the setting of OFF HOOK SP.
Displays an alarm currently in progress. When the cause of the
alarm is eliminated, the alarm display will disappear. Explain to
8. ALARM
the user that information displayed on this window helps the user
conduct troubleshooting in case of equipment failure.
Entering this menu requires entry of a password.
Used to install and perform maintenance of equipment. This
9. SERVICE
menu includes DSC- and RT-related system settings and a more
detailed maintenance menu.
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.

Chapter 4. System setting

Description
assignment of commonly-used operation
to a specific key.
configuration of antenna.
change requires entry of a password.