Time Out] - Furuno FS-1575 Service Manual

Ssb radiotelephone
Hide thumbs Also See for FS-1575:
Table of Contents

Advertisement

4.3.6 [6. TIME OUT]

This submenu is used to make setting of time required for the system to return to a
window to which it entered when performing no operation after entering the
OPERATION/SETTING window from the RT or SCAN window.
Submenu
Set Value
10 MIN
1. MENU END
NO
TIMEOUT
15 MIN
2. DSC
GENERAL
NO
TIMEOUT
15MIN
3. RX DISTRESS
NO
TIMEOUT
10 SEC
30 SEC
4. SSB
10 MIN
10 SEC
30 SEC
5. TELEX
10 MIN
NO
TIMEOUT
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Table 4.3.3 List of TIME OUT Setting Submenus
Description
Makes setting of operation timer on the MENU window.
Setting this submenu to 10 minutes will return to a
window before entering the MENU window as long as no
operation is performed for a period of 10 minutes.
Makes setting of reception windows except for the
DISTRESS ALERT RECEPTION window and the
window operation timer.
When setting this submenu to 15 minutes, the DSC
procedure will be automatically cleared and disappear
from the multi-procedure tab area (not from the log) if no
operation is performed for a period of 15 minutes.
Makes setting of the DISTRESS ALERT RECEPTION
window and the window operation timer.
When setting this submenu to 15 minutes, the display will
return to the RT window if no operation is performed for a
period of 15 minutes.
Makes setting of operation timer when "emission type" on
the RT window is set to SSB or LSB.
For example, setting this submenu to 10 seconds will
make the RT icon mark disappear from the
multi-procedure tab area.
Makes setting of operation timer when "emission type" on
the RT window is set to TELEX (TLX).
For example, setting this submenu to 10 seconds will
make the RT icon mark disappear from the
multi-procedure tab area if no operation is performed for
a period of 10 seconds.
However, during transmission or standby at NBDP
frequency, this submenu is set to NO TIMEOUT.
4-19
4.3 SYSTEM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-2575Fs-5075

Table of Contents