1.7 Optional operation of IB-583 / IB-585 (See 4-97 to -119)
1) Rewriting ID: Type "ID
2) Rewriting AAB: Type "ANSWER
3) Access to [F11] Setup menu: Type "DP6" in all capital letter.
4) Access to [F6] System menu: Type "DP6" in all capital letter.
5) Selecting Russian mode: Press Power + [R] keys.
6) Switching between Russian and English for characters: Press [Shift] + [Alt] keys
7) Conducting IB-585: [F6] -> Self-Test: Type "DP6" in all caps.
2. Software
Software package number is "APP: 0550243-xx.xx." To verify the number, select
[MENU] -> 1.TEST -> 1.DAILY TEST.
To update the software, it is just needed to make a LAN connection (172.31.5.3/16)
between the transceiver unit and the PC, and then click on the "nUP_FSXX75.bat" file.
After update, no actions such as Memory Clear need not to be taken. Furthermore, no
setting parameters are deleted.
Note)
Loading a program to the T-CPU of the Transceiver unit will automatically load the
same to the C-CPU of the Control unit. The 78K CPU program used to
communicate with the NBDP terminal unit will also be automatically loaded.
If combinations of T-CPU program, C-CPU program, and 78K CPU program are
different, programs will be automatically loaded from T-CPU to C-CPU and 78K
CPU.
For example, when the Control unit is replaced, programs will be automatically
loaded to the C-CPU, 40 seconds after turning ON the power.
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CODE" in all caps.
(space)
CODE" in all capital letter.
(space)
3
Summary