6.7 Erasing FS-2575C Software

Clicking on "SOFTWARE ERASE" on the "OTHER" window will erase backup data
saved in the C-CPU application program "APP" and in the flash ROM of C-CPU of the
FS-2575C unit and return set values to their default.
Furthermore, software can be erased by FS-2575C unit.
Clicking on "SOFTWARE ERASE" will automatically install C-CPU programs
from T-CPU.
No.
Data To Be Erased
1
SQ setting
2
5.SYSTEM -> 1.SQ FREQ.
3
5.SYSTEM -> 2.KEY Assign -> F1
4
5.SYSTEM -> 2.KEY Assign -> F2
5
5.SYSTEM -> 2.KEY Assign -> F3
6
RT SETUP window check meter
7
5.SYSTEM -> 3.PRINT -> 1.TX MSG
8
5.SYSTEM -> 3.PRINT -> 2.RX MSG
9
5.SYSTEM -> 3.PRINT -> 3.DAILY TEST
10
Handset volume setting
11
7.AUDIO -> 1.KEY CLICK
7.AUDIO -> 3.ORDINARY ALARM ->
12
1.SAFETY
7.AUDIO -> 3.ORDINARY ALARM ->
13
2.ROUTINE
14
7.AUDIO -> 2.OFF HOOK SP
15
7.AUDIO -> 5.SIDE TONE
16
7.AUDIO -> 6.SIDE TONE LV
9.SERVICE -> 2.DSC SETUP -> DISTRESS
17
ALARM
9.SERVICE -> 6.MAINTENANCE LOG ->
18
3.SW UPDATE LOG
NIGHT MODE, DAY MODE LED & LCD
19
setting
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Table 6.7.1 FS-2575C Data to be erased
Default
OFF
ON/OFF
1000Hz
500Hz to 2000Hz
· TX/RX FRE
TX / RX
· RX FREQ
FREQ
· MODE
DAILY
· AGC
TEST
· TX PWR
· TX MONITOR
· TEST CALL
· MSG FILE
TEST
· DAILY TEST
CALL
· LOG
· INTERCOM
· CLARIFIER
IA
IA / IC / VC / RF / VS
MANUAL
AUTO / MANUAL
MANUAL
AUTO / MANUAL
MANUAL
AUTO / MANUAL
10
1 to 20
2
0 to 3
5
0 to 5
5
0 to 5
MUTE
SP ON / MUTE
600
400 to 1000
32
0 to 63
16
0 to 31
deleted
DAY
Day mode: Max.
mode