8.1.5 When program version is different between T-CPU and
C-CPU
When the system consisting of a combination of different program version between the
FS-xx75T and FS-2575C units is connected, the C-CPU program will automatically be r
downloaded to the C-CPU program saved in the T-CPU after a lapse of approximately
40 seconds since the power turns ON.
1) Turn ON the power. When the "Initializing..." popup window disappears, the popup
window (1) shown below will appear on the FS-2575C window, shortly followed
by the popup window (2). Then, press the [ENTER] knob on the FS-2575C unit.
Even if the [ENTER] knob is not pressed, the FS-2575C program update will
automatically be initiated after a lapse of 30 seconds.
(1)
(3)
2) The message saying "Writing---" will switch to "Completed." With that, the
FS-2575C program update is completed.
The window will black out once, and then the "Initializing..." popup window will
automatically appear to display the RT window.
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Press the [ENTER] knob or wait for a
period of 30 seconds.
(2)
The window will black out once, and then erasing
(deletion) of program will be initiated.
(4)
Upon completion of erasing, writing of
program will be initiated.
8-12
8.1 FS-xx75 Updating Program