Ricoh G133 Service Manual page 533

Table of Contents

Advertisement

Enables or disables the remote service function.
[0 to 1 / 0 / 1 /step]
0: Disabled
1: Enabled
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
007
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
RCG Connect Timeout
008
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 10 / 1 second /step]
RCG Write Timeout
009
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
RCG Read Timeout
010
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
Port 80 Enable
Enables/disables access via port 80 to the SOAP method.
011
[0 or 1 / 0 / – ]
0: Disabled
1: Enabled
Function Flag
021 This SP displays the embedded RCG installation end flag.
0: Installation not completed
1: Installation completed
022 Install Status