Ricoh G133 Service Manual page 358

Table of Contents

Advertisement

Service Mode Table
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: HH] Charge Roller AC Current Adjustment for HH
(Color)
2011
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
2012
[Charge Output Control]
001 AC Voltage
2013
[Environmental Correction: PCU]
Current Environmental:
001
Display
G133
*ENG
[0 to 3 / 1.49 / 0.01 mA/step]
*ENG
[0 to 3 / 1.52 / 0.01 mA/step]
*ENG
*ENG
*ENG
[0 to 3 / 1.48 / 0.01 mA/step]
*ENG
[0 to 3 / 1.5 / 0.01 mA/step]
*ENG
*ENG
Selects the AC voltage control type.
[0 or 1 / 0 / 1/step]
*ENG
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)
Displays the environmental condition,
which is measured in absolute humidity.
*ENG
[1 to 5 / – / 1 /step]
1: LL (LL <= 4.3 g/m
5-36
3
)
SM

Advertisement

Table of Contents
loading

Table of Contents