Ricoh G133 Service Manual page 253

Table of Contents

Advertisement

No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller overheat 1 (software error)
The detected fusing temperature stays at 215°C for 1 second.
Defective PSU
Defective IOB
543
A
Defective EGB
Related SC code: SC 553
1.
Replace the PSU.
2.
Replace the IOB.
3.
Replace the EGB.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller overheat 1 (hardware error)
During stand-by mode or a print job, the detected heating roller
temperature reaches 220 °C.
Defective PSU
Defective IOB
544
A
Defective EGB
Defective fusing control system
Related SC code: SC 543
1.
Replace the PSU.
2.
Replace the IOB.
3.
Replace the EGB.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
547
D
Zero cross error
The zero cross signal is detected three times even though the
heater relay is off when turning on the main power.
SM
4-37
SC Table
G133