Ricoh G133 Service Manual page 231

Table of Contents

Advertisement

No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: Bk
The PFGATE ON signal does not assert within 5 seconds after
processing the image in normal job or MUSIC for start position [K].
Defective ASIC (Lupus)
230
D
Poor connection between controller and EGB.
Defective EGB
1.
Check the connection between the controller board and the EGB.
2.
Replace the EGB.
3.
Replace the controller board.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: Bk
The PFGATE ON signal still asserts within 5 seconds after
231
D
processing the image in normal job or MUSIC for end position [K].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after
232
D
processing the image in normal job or MUSIC for start position [Y].
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
233
D
FGATE OFF error: Y
The PFGATE ON signal still asserts within 5 seconds after
SM
4-15
SC Table
G133

Advertisement

Table of Contents
loading