No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
1.
Replace the controller board.
SHM register error
The initialization of bus connection or read for SHM fails.
The register of SHM is different from specified value.
[0B10]
Defective connection bus
Defective SHM
1.
Replace the controller board
Self-diagnosis error: ASIC
The CPU checks if the ASIC timer works correctly compared with the
CPU timer. If the ASIC timer does not function in the specified range,
this SC code is displayed.
System firmware problem
[0D05]
Defective RAM-DIMM
Defective controller
1.
Reinstall the controller system firmware.
2.
Replace the RAM-DIMM.
3.
Replace the controller board.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
CTL
Self-diagnostic error: HDD (Hard Disk Drive)
822
B
[XXXX]: Detailed error code
[3003]
Timeout error
[3004]
Command error
When the main switch is turned on or starting the self-diagnostic, the
-
-
HDD stays busy for the specified time or more.
Loose connection
-
-
Defective HDD
SM
4-63
SC Table