Alter Chime Circuits

This option allows an alternative method of
programming circuits as "chime". Three types of chime
tones are available:
Chime 1
Generates a single two-tone chime sound.
Chime 2
Generates a double two-tone chime sound.
Chime 3
Generates a triple two-tone chime sound.
When a circuit is programmed as chime it will only
generates the relevant chime tone from remote
keypad sounders and extension loudspeakers assigned
to the same ward(s) as the detection circuit.
If configuration option 15 is programmed as "Chime
Visible", the display will show the circuit that caused the
chime.
5
Engineers menu 2
Chime circuits
0001 Disabled
Enter the circuit number
A C
/
FRONT DOOR
Circuit No.
0002 Disabled
FRONT DOOR
0001>Disabled
1
2
3
0
Chime Circuits Flowchart

Alter 24Hr Group

Any combination of wards can be assigned to the 24hr
group. Circuit types "24hr" and "Auxiliary" with the
"Omittable" attribute within the selected ward will be
isolated when the selected ward is omitted using user
menu 1 option 6 (24hr omit/unomit). Only the wards that
are assigned to the 24hr group can be selected by the
user.
[2-5]
[
to scroll
Circuit text
[
= Chime 1
= Chmie 2
= Chime 3
= Disabled
[
[2-6]
Engineers menu 2
6
Alter 24hr group
Wards 24hr group
A,B,*,*,.,.,.,.
1 8
-
A C
/
and wards I-P
Ward Status Key
*
= Ward not selected.
.
= Ward not available.
A-P
= Wards selected.
Alter 24hr Group Flowchart

Print System Log

The system log stores 4000 events, if a printer is
connected to the system it is possible to print a selected
number of events. By specifying an offset you can print
the selected number of events from the offset point
rather than the last event, e.g. if you specify 100 events
with an offset of 1000, you will get a printout of events
2900 - 3000. Once the print-out has been started it can
only be stopped by selecting this option again and
entering "0000" for the number of events.
Engineers menu 2
7
Print system log
How many events
Enter number of events.
With offset of:-
Enter offset.
Press
[
Print System Log Flowchart
Engineer's Menu 2
[
Wards
toggle wards.
to scroll wards A-H
[
[2-7]
[
0030
[
0000
to start printing.