Test Node Outputs; Confirm Network Devices; Test Keypad Display; View Network Devices - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

TS2500 Installation Manual

Test Node outputs

This test routine allows the engineer to test all Node
outputs.
[ENT] to test :-
6
Node outputs
Network &
2,16A XNode
device No.
is turned on
Enter network & device No.
e.g. 216 = Network 2 device 16
B
to toggle output on or off
Test Node Outputs Flowchart

Confirm Network devices

This option allows the engineer to confirm the correct
number of devices are connected to the system. After
confirmation any changes in the system hardware will
cause the "RELEARN REQUIRED" message to be
displayed on all remote keypads.
7
[ENT] to CONFIRM
Network devices
[ENT] to CONFIRM
No. of devices
002 LEC2 on sys
Number of TS700LECs
[
[ENT] to CONFIRM
No. of devices
012 REMS on sys
Number of Remotes
[
[ENT] to CONFIRM
No. of devices
000 NODE on sys
Number of TS900Nodes
[
[ENT] to CONFIRM
No. of devices
016 XNODE on sys
Number of XNodes
[
Confirm Network Devices Flowchart
[
Output state
]
[
to confirm
to confirm
to confirm
to confirm
]

Test Keypad display

This test routine allows the engineer to test the LCD on all
TS900 remote keypads.
8
[ENT] to test :-
Keypad display
888888888888888
888888888888888
Test Keypad Display Flowchart

View Network devices

This test routine allows the engineer to view the status of
each device connected to the network. The
information displayed will depend on the device type.
9
[ENT] to view :-
Network devices
Remote
1,01
Keypad
A-H B-H T-H
1 8
-
A C
/
Nodes
2,01
13.50 FH TH HH**
B to veiw circuits
2,01
1H2H3H4H5H6H7H8H
FH = Fuse healthy
FB = Fuse blown
TH = Tamper Healthy
TA = Tamper active
View Network Devices Flowchart
+
When selecting this option the remote keypad
that you are using is the first device to be
displayed.
Engineers Menu 3
[
]
[
Remote
Tamper Status
Circuit Status
to select network
to scroll device
XNode
Rems 1 - 4
tamper status
Tamper status
Fuse status
XNode voltage
XNode
Circuit status
]
69