Screened Cable; Electromagnetic Compatibility; Xnode Wiring - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

System Design
Method 1
20m
Control Panel
A (+)
Node = 60mA
B ( - )
Total = 180mA
Network
120mA taken by detectors
Note:
Voltage at Node
The +ve supply from
the panel must remain
isolated from the +ve
of the Remote PSU.
Method 2
20m
Control Panel
A (+)
Node = 60mA
B ( - )
Total = 180mA
Network
120mA taken by detectors
Note:
Voltage at Node
The +ve supply from
11.87 V
the panel must remain
isolated from the +ve
of the Remote PSU.

Screened Cable

Screened cable may prove necessary if the installation
site has equipment that produces high levels of R.F.
(Radio Frequencies), e.g. heavy industrial plant like
welding equipment etc. If screen cable is required you
should adhere to the following guidelines:
1.
The screen on the cable should only be connected
to mains earth at the control panel.
2.
The continuity of the cable screen is most important
and screening MUST be continuous along the full
length of the network.
3.
If the network cable enters any metal enclosures,
make sure the screen remains isolated from the
case.

Electromagnetic Compatibility

When used as intended this product complies with EMC
Directive (89 /336 /EEC) by meeting the limits set by the
standards BS4737, EN50082-1 1992 and EN50130-4
1993. The following installation guidelines must be
followed.
8
20m
Node 1
Node 2
I = 180 mA
Node = 60mA
Total = 180mA
AUX
AUX
120mA taken by detectors
Voltage at Node
7.84 V
8.42 V
20m
Node 1
Node 2
I = 180 mA
Node = 60mA
Total = 180mA
AUX
AUX
120mA taken by detectors
Voltage at Node
12.45 V
Figure 3. Connecting Remote Power Supply Units
20m
20m
Node 3
I = 540 mA
I = 360 mA
Node = 60mA
Total = 180mA
AUX
120mA taken by detectors
Voltage at Node
9.57 V
20m
20m
Node 3
I = 360 mA
I = 360 mA
Node = 60mA
Total = 180mA
AUX
120mA taken by detectors
Voltage at Node
13.60 V
519 XB
1A PSU
0V
12V
1.
External cables must be connected using cable
entries or knockouts provided.
2.
When routing external cables inside the product
they must be:
(a)
Kept as short as possible.
(b)
Routed close to the housing.
(c)
Kept as far as possible from the electronics.
3.
Any modifications other than those stated in this
manual, or any other use of this product may cause
interference and it is the responsibility of the installer
to comply with the EMC and Low Voltage Directives.

XNode Wiring

The XNode requires a 4 core cable for interconnection,
and up to 16 may be connected in a "daisy-chain" or
"star" configuration. The distance between each
XNode must not exceed 100 metres. The total distance
to last XNode must not exceed 1000 metres. Power for
detectors is provided by the Aux. +/- terminals.
TS2500 Installation Manual
20m
Node 5
Node 4
I = 720 mA
Node = 60mA
Node = 60mA
Total = 180mA
Total = 180mA
AUX
120mA taken by detectors
120mA taken by detectors
Voltage at Node
Supply voltage at the Node
13.60 V
11.30 V
519 XB
1A PSU
-
+
20m
Node 5
Node 4
I = 180 mA
Node = 60mA
Node = 60mA
Total = 180mA
Total = 180mA
AUX
120mA taken by detectors
120mA taken by detectors
Voltage at Node
Voltage at Node
11.87 V
12.45 V
AUX
AUX