User Functions

SETTING THE SYSTEM

1.
Enter your passcode - the (UNSET) light will
flash.
2.
Wait 5 secs until the (FUNCTION) light goes out
and the exit tone will start.
designated exit route, closing the door.
3.
The system is set when the exit tone stops and
the two tone confirmation tone is heard.
NOTES:
A)
If the exit tone continues and (if fitted) the
strobe light on the bell box is flashing the
system has not set and you must re-enter the
premises, re-enter the passcode and start
again.
B)
If you change your mind whilst setting the
panel and wish to unset it again press (0) (END)
or wait until the (FUNCTION) light goes out and
re-enter your passcode.
PART SET THE SYSTEM
1.
Enter your passcode - the (UNSET) light will flash
2.
Press [7] (OMIT A) OR [9] (OMIT B) as appropriate
- the zones omitted will flash.
3.
After a pause the exit tone will start.
4.
The system is part set when the exit tone stops.
The following options may be accessed by entering
the USER 1 passcode IN REVERSE ORDER (eg for
passcode 5678 - enter 8765) followed within 5
seconds by the function key you require. These
facilities are not available to User 2 who is restricted
to Set, Part-set and Unset activities.
NOTE: TS500 enter code in forwards and not in
reverse for following functions
Testing Sounders
1.
Enter User 1 passcode IN REVERSE and the
tone will start - press [1] (BELL TEST) immediately.
2.
All panel lights illuminate followed by 5 second
sequential activations of internal sounders,
external sounders and strobe (if fitted).
3.
Panel returns to [UNSET] condition on
completion of testing.
Testing Detectors
1.
Enter User 1 passcode IN REVERSE and the
tone will start - press [2] (WALK TEST)
immediately.
496525 Issue A
2.
3.
4.
Change User 1 Passcode
Leave via the
1.
2.
3.
4.
5.
6.
Change User 2 Passcode
1.
2.
3.
4.
5.
6.

Selecting Chime

With the system unset you may wish to be alerted
when door contacts or detectors are activated. You
can set nominated devices to "CHIME":
1.
2.
3.
4.
5.
6.
Change Part Set Areas
If you wish to re-arrange your part-set areas:
1.
2.
3.
4.
9 of 10
Activate selected detectors or door contacts
and smoke detectors if fitted.
Zone light illuminates and two tone sounder is
heard for each device activated.
Press [0] (END) to complete test - [UNSET] will
illuminate.
Enter User 1 passcode IN REVERSE and the
tone will start - press [4] (USER 1) immediately
Four zone lights illuminate and 15 seconds is
allowed to commence entry of the new code.
Enter new passcode extinguishing the four
zone lights.
Four zone lights illuminate again.
Repeat new passcode (as confirmation).
Two tone confirmation sound heard - new
passcode accepted - [UNSET] will illuminate.
Enter User 1 passcode IN REVERSE and the
tone will start - press [6] (USER 2) immediately.
Four zone lights illuminate and 15 seconds is
allowed to commence entry of the new code.
Enter new User 2 passcode extinguishing the
four zone lights.
Four zone lights illuminate again.
Repeat new User 2 passcode (as
confirmation).
Two tone confirmation sound heard - new User
passcode accepted - [UNSET] will illuminate.
Enter User 1 passcode IN REVERSE and the
tone will start - press [5] (CHIME) immediately.
Any zones set to chime will illuminate.
To add or delete chime zones press the
relevant zone number within 15 seconds.
Zone lights indicate status (LIT=CHIME,
UNLIT=NORMAL).
When satisfied press [0] (END).
Two tone confirmation sound heard - [UNSET]
will illuminate.
Enter User 1 passcode IN REVERSE and the
tone will start - press [7] (OMIT A) OR [9] (OMIT B)
immediately as required.
Zone lights flashing indicate those zones
omitted
To add or delete omit zones press the relevant
zone number within 15 seconds.
Zone lights indicate status