TS2500 Installation Manual
Trig Custom o/p
A custom circuit with the "Trig Custom o/p" attribute will
activate the relevant "Custom Circuit" output type, e.g.
If custom circuit 3 is programmed to trigger its custom
output, it will activate "Custom cct 3" output (system
output No 82).
Each attribute can be assigned to the custom circuit so
that they are only activated for the following conditions:
Unset
Attributes assigned to the custom circuit for the unset
mode will only operate when the ward that the circuit is
assigned to is in an unset state.
Part
Attributes assigned to the custom circuit for the part set
mode will only operate when the ward that the circuit is
assigned to is set and one or more wards are unset, i.e.
the system is in a part set state.
Full
Attributes assigned to the custom circuit for the full set
mode will only operate when the system is fully set, i.e.
all defined wards set.
Custom Circuit Text
Up to 11 characters can be assigned to each custom
circuit. This text is displayed when programming circuits.
B
Engineers menu 3
Custom circuits
[ENT] to edit :-
custom circuit 1
1 8
-
scroll custom circuits
Bell required
>Unset,Part,Full
Digi required
>
Sounder required
C
>
A
Warning required
>
Trig Custom o/p
>
1
2
3
Custom Cct1
[B] to edit text
B to edit text
[ to accept
Custom Circuits Flowchart
[
or
A C
/
to
[
to edit
,
,
,
,
,
,
,
,
= Toggle Unset
= Toggle Part
= Toggle Full

Digi/Modem Options

This option allows the engineer to program the plug-on
digicom or digi-modem.
Engineers menu 3
Digi/Modem opt.
[ENT] to edit :-
1

Call back no.1

2
[ENT] to edit :-

Call back no.2

3
[ENT] to edit :-

Call back no.3

[ENT] to edit :-
4
C
Modem password
A
5
[ENT] to edit :-
Modem site no.
6
[ENT] to edit :-
Digi program
7
[ENT] to edit :-
Digi BAUD rate
8
[ENT] to edit :-
COM1 BAUD rate
9
[ENT] to edit :-
Internal digi
0
[ENT] to
Reset Digicom
Digi/Modem Options Flowchart
Call Back No.1
This option allows the first call back telephone number
to be programmed.
Call Back No.2
This option allows the second call back telephone
number to be programmed.
Call Back No.3
This option allows the third call back telephone number
to be programmed.
Engineers Menu 3
[3-C]
[