The TS900 ID Node can be used as an alternative to the
standard TS900 or XNODE. The ID Node provides a single
ID Detector Loop that allows you to connect up to 30 ID
devices. Several configuration options allow you to use
the TS900 ID Node on its own or with existing TS900
Nodes or XNodes. You can connect a maximum of two
ID Nodes to one network.
Fit jumper link to disable
tamper switch
Tamper switch
JP2
JP2
FITTED
NO
TAMPER
Address
1
2
Bit-Switch
3
4
Output Module
OUTPUT
MODULE
Connector
Cable
Entry
1 AMP
AUX 12V
1 Amp Auxilliary
Fuse
Node Network
+ -
AUX
'IN' connections
12V
A
B
F
G
NETWORK IN
Mains power indicator
Auxilliary 12V output for
(flashes when mains
powering detectors
power is off)
Figure 16. TS900 ID NODE PCB Layout
1
2
ON
off
off
ON
ON
off
off
ON
24
Cable
Entry
TS900 I.D. NODE
OUTPUTS
A+
Switched +ve
B+
Outputs
C+
D+
Cable
Entry
-
+
E-
Switched -ve
F-
Outputs
G-
H-
+ -
C D E
Node Network
DTR
REMOTE
LOOP
NETWORK
'OUT' connections
A
B
F
G
NETWORK OUT
Cable
Entry
Detector
Loop-in connections for
Loop
the Remote Network
3
4
Nodes Simulated
off
off
1, 2, 3 & 4
off
off
5
off
ON
1, 2 & 3
off
ON
4 & 5
Address Bit Switch Options
Installing a TS900 ID NODE
You can site the ID Node either inside the control panel
or remotely. If you site the ID Node remotely the
maximum cable length is 100m. Note that the supply
voltage at the ID Node MUST be capable of supplying
power for all the detection devices connected to the
node. If there is not enough power then you will need to
fit a remote power supply to the node.
1. Separate the cover. Use a screwdriver to push two of
the clips (left or right) inwards from the base indents and
lift the cover clear.
2. To fit an ID Node inside the control panel remove the
ID Node PCB from its base and secure it inside the
control panel using self-adhesive feet. Disable the ID
Node tamper switch, if necessary, by fitting the jumper
link across JP2 (see Figure 6).
3. To fit an ID Node remotely, hold the base in position
and mark the four securing holes. Drill and plug the wall
as required. Pass all cables into the base through the
cable entry points as necessary. Secure the base to the
wall using the appropriate fixing screws.
4. Connect "Node Network" cables to the appropriate
terminals (see Figure 6).
5. Connect the ID Detection Loop to the + and - DTR
Loop terminals. Take power for the detectors from the +
and - AUX 12V terminals (see Figure 6).
Set the Address Bit-Switch to the required position (see
table below).
For more information see "TS900 ID Node Installation
Instructions" part number 18981.
Biscuits Addressed
Node Outputs
1 to 30
1-8 (A-H)
1 to 8
9-10 (A-B)
1 to 24
1-6 (A-F)
1 to 16
7-10 (A-D)
TS2500 Installation Manual