Engineer's Menu 2

Start Call Back

If the the system is fitted with a DC58M digi-modem, it is
possible for the installation engineer to initiate an
upload sequence to a remote site (normally the alarm
company). Once the communication link is established
with the remote site, data can be sent and received
from the control panel. This feature is only compatible
with Menvier Lineload software version 2.2 or above.
A
Engineers menu 2
Start call back
01275870078
Call No.1 Office
1
= Call back No.1
2
= Call back No.2
3
= Call back No.3
B
= Dial this number
[
= Start call back
Engineer on Site
10:20 Wed 04 JAN
Start Call Back Flowchart

Reset User Code 1

This option allows the installation engineer to reset the
master user (user 001) back to the factory default code
of "5678". This feature is useful when the master user has
forgotten their passcode or has accidentally changed it
without realising. This operation is logged.
Engineers menu 2
B
Reset user code1
[ENT] to DEFAULT
user code 1.
[ = Reset code
Reset User Code Flowchart
60
[2-A]
[
Tel No.
Call back No.
[2-B]
[

Set BST/GMT Date

This option allows the engineer to specify the dates at
which BST starts and ends. The system will then add an
hour at 2:00 am on the BST date and subtract an hour at
2:00 am on the GMT date.
C
Engineers menu 2
Set BST/GMT date
Enter BST date:-
Enter BST date e.g. 30/03
Enter GMT date:-
Enter GMT date e.g. 26/10
Set BST/GMT Dates Flowchart

Rem Service Option

This option allows the engineer to enable or disable the
remote service option.
0
Engineers menu 2
Rem service opt.
Rem service call
is DISABLED
Remote Service Options Flowchart
TS2500 Installation Manual
[2-C]
[
30/03
[
26/10
[
[2-0]
[
B to toggle
[

Advertisement