Menvier Security TS2500 Installation & Programming Manual page 52

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineer's Menu 1
28
Latching 24hr (Default)
24 hour detection circuits will cause an alarm
when triggered and will only be re-armed after a
full reset, i.e. Enter passcode to silence alarm,
then enter passcode followed by [ESC] to reset the
alarm.
Nonlatching 24hr
24 hour detection circuits will cause an alarm
when triggered. On entering a passcode the
alarm is silenced, if the same circuit is activated
before carrying out a reset, the
re-triggered.
29
Access code only (Default)
The "System Access" and "Ward Access" output
types are triggered only when a "Access" type
passcode is entered.
Access all codes
The "System Access" and "Ward Access" output
types are triggered when any passcode is
entered.
30
Answer anytime (Default)
Wh en usi ng a DC 58M digi -mo de m, the
digi-modem will always attempt to answer
incoming calls.
Answer o/p 1 on
The digi-modem will only attempt to answer
incoming calls when "Custom Output 1" is on.
31
NVM is Unlocked (Default)
The NVM can be reset to the factory defaults by
shorting the FACTORY RESTART pins during
power-up.
NVM is Locked
The NVM cannot be reset by shorting the FACTORY
+
RESTART.
If the "NVM is LOCKED" option is selected it is
imperative that the engineer code is not lost
or forgotten. If this is the case then the only
way of returning the system to its factory
default setting is by returning the control
panel PCB to Menvier Security.
32
Unshunt. no exit (Default)
The use of a shunt code to reinstated a selected
group of circuits will not initiate the exit procedure.
Unshunt & exit
The use of a shunt code to reinstated a selected
group of circuits will initiate the exit procedure.
33
Ignore errors (Default)
When attempting to set with one or more circuits in
fault the system will continue with the exit
procedure but will display the circuits that are in
fault. If the circuits are not cleared at the end of
the exit procedure a set fail condition will occur.
View exit errors
When attempting to set with one or more circuits in
a fault the system will prompt the user that a fault
exists and the display will scroll through the circuits
48
that are in fault. Once the faulty circuits are
cleared the user will be prompted to press [ENT] to
continue with the exit procedure.
34
Mimic. All times (Default)
When using output modules or outputs that are
programmed as circuit mimic, the outputs will
mimic the circuit at all times.
Mimic. Set only
When using output modules or outputs that are
programmed as circuit mimic, the outputs will only
alarm
mimic the circuit if the circuit is in a set ward.
TS2500 Installation Manual
9
Engineers menu 1
Configuration
[
Configuration 00
Bell is an SAB
Enter 00 - 34 or use
A C
/
to scroll.
B
to toggle setting
Configuration
Bell is an SCB
Configuration Flowchart