Mains Connection

The mains supply is connected to a 3 way "Euro Type"
+
fused terminal block,which is fitted with a 315mA fuse.
All electrical connections should be carried out
by a qualified electrician and must comply with
+
the current IEE regulations.
To comply with European regulations the supply
should be fed from a readily accessible
+
disconnect device, e.g. un-switched fused spur.
When making mains connections it should be
ensured that if the cable slips in such a way as to
place a strain on the conductors, the protective
earthing conductor will be the last to take the
strain.
To transformer
Figure 9. Mains Supply Connections
FUSE 315mA

Battery Connections

A single 17Ah battery or two 7Ah batteries can be
installed inside the control panel to provide continuous
system operation in the event of a mains failure. A set of
battery leads are provided in the spares pack to allow
connection between the battery and control panel.
+
12V 17Ah Battery
-
+
12V 7Ah Battery
-
+
12V 7Ah Battery
L
-
E
N
Figure 10. Battery Connections
If the mains power to the control panel fails, the standby
battery will take over and maintain the system. In order
to safeguard the battery from full discharge the control
panel automatically isolates the standby battery when
its voltage falls below 9.5V. When the mains power is
restored the system will power-up and the reconnect
the battery, then continue to recharge. If the system is to
be tested using only the battery (no mains supply
available) then the "Kick Start" pins must be momentarily
shorted to enable the battery.