View Circuits; Set System Time; Set System Date; Change Passcode - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineer's Menu 2

View Circuits

Each detection circuit may be viewed to ascertain its
status. The circuit status conditions and resistance are
shown below:
Status
Response
Normal
Healthy
None
Active
Alarm
Tamper
Tamper
Shorted
Alarm
1
Engineers menu 2
View circuits
Loading bay door
0001 Healthy
A C
/
the circuits or enter the
circuit number
Loading bay door
Circuit No.
0001 Active
[ alternates between the
circuit text & circuit location
TSLEC8
Circuit No.
0001 Active
View Circuits Flowchart

Set System Time

The system time is displayed in a 24hr format on all
remote keypads and is also used to time stamp events
in the system event log. The BST/GMT changeover can
be programmed to automatically occur on specific
dates, see page 60.
2
Engineers menu 2
Set system time
Enter new time:-
Enter new time:-
New time
Set System Time Flowchart
54
[2-1]
Min.
Max.
54 Ω
2.2 KΩ
4.1KΩ
6.9 KΩ
4.1 KΩ
54 KΩ
54 KΩ
0 Ω
0 Ω
53 Ω
[
to scroll through
Circuit text
Status
Location
AOS
Shunted
]
Omitted
No Activity
[2-2]
[
12:23 GMT
Enter time
e.g. 1605
GMT or BST
16:05 GMT
B
to toggle
[

Set System Date

The system date is displayed in a day/date/month
format on LCD remote keypads. it is also used to provide
date stamps for events in the system log.
3
Engineers menu 2
Set system date
Enter new date:-
Enter the date as
a 4 digit number
Enter new date:-
New date
Today is :-
Current day
> Su............
Select the day 1-7.
1=Sunday, 7=Saturday
e.g. 3 for Tuesday
Today is :-
New day
> ....Tu........
Set System Date Flowchart

Change Passcode

This option allows the engineer to change their
passcode. The default passcode is 1234 if 4-digit
passcode are enabled and 123400 if 6-digit
passcodes are enabled.
Engineers menu 2
4
Change passcode
Enter new code..
Enter new passcode
Enter new code..
New code
Change Passcode Flowchart
TS2500 Installation Manual
[2-3]
[
01/01
e.g. 1709
17/09
[
[
[2-4]
[
----
e.g. 2580
2580
[

Advertisement

Table of Contents
loading