Custom Text Menu; Reset Message; Location Text; Printer Header - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineers Menu 3

Custom Text Menu

This menu option allows the installation engineer to edit
the following text messages:

Reset Message

The default reset message "CALL ENGINEER TO RESET
SYSTEM" can be personalised by the engineer, e.g. the
message may be programmed to read "CALL XYZ
ALARMS ON 0181-1234567".

Location Text

This option allows the engineer to program a 32
character location message. When "Engineers menu 1"
is selected the engineer can view this message. This
can be used to provide the location details for the
control panel, e.g., "C P located in reception area", thus
assisting service engineers unfamiliar with the site.

Printer Header

This option allows the installation engineer to program a
32 character printer header message. This is printed
whenever a system or log printout is taken from the
system. This can be used as a site reference, e.g., "ABC
Company Job No123456".

Remote Reset Message

The default remote reset message "CALL A.R.C FOR
REM.RESET CODE" can be personalised by the
engineer, e.g. the message can be programmed to
read "CALL 0181 121212 FOR RESET CODE".

Printer Prefix

This option allows the engineer to specify a 16 character
message which is prefixed to every event sent to the
printer.

Banner Message

Normally when the system is unset the bottom line of the
display shows the time and date, and the top line is left
blank. This menu option allows the engineer to program
or edit a 16 character "Banner" message which is
displayed on the top line. This may be used to display
the company's name, e.g., "Blogg Alarms", "ABC
Security" etc.

Part Set Banner

The part set banner is a 16 character message
displayed on the top line of the display whenever the
system is part set. If the message is left blank the top line
of the display will show the wards that are set. If the
message is programmed the top line of the display will
show the message, e.g., "System Part-Set".
66
[3-7]

Aux. Tamper 1/2

The control panel has two auxiliary tamper inputs, this
option allows the engineer to program a 16 character
text description for each input.

Modem String

For future use.
Cursor
TS2500 Installation Manual
7
Engineers menu 3
Custom text menu
[
[ENT] to edit :-
Reset message
A C
/
to scroll
0 = Reset message
1
= Location text
2
= Printer header
3
= Remote reset msg
4
= Printer prefix
5
= Banner message
6
= Part set banner
7
= Aux. tamper 1
8
= Aux. tamper 2
9
= Modem string
[ to edit
MENVIER SECURITY
^anner message
Use keys to edit circuit text
[
Custom Text Menu Flowchart

Advertisement

Table of Contents
loading

Table of Contents