TS2500 Installation Manual

Custom Outputs

This option allows the engineer to program the eight
custom outputs type. The diagram below represent the
logic circuit for the custom output.
1
2
3
Input
4
5
6
E ac h s wit ch in th e diagra m re pre se nts a
programmable output type, therefore the
output will only activate when the correct combination
of output types are active.
Switches 1 - 4 perform a logical "OR" function and
switches 5 - 8 perform a logical "AND" function.

Custom Output - Example 1

This example shows how the "OR" function can be used
so that the "Custom Output" activates when circuit 0001
or 0005 or 0016 causes an alarm condition. The table
below shows how each switch is programmed to
achieve this.
OR
1
Circuit 0001 Alarm
2
Circuit 0005 Alarm
3
Circuit 0016 Alarm
+
4
System Always Off
When using the "Custom Output" for "OR" logic
only, all unused switches must be programmed
to the type "Always Off".

Custom Output - Example 2

This example shows how the "AND" function can be
used so that the "Custom Output" only activates when
the system is ward A is set and time switch 1 is active. The
table below shows how each switch is programmed to
achieve this.
OR
1
System Always Off
2
System Always Off
3
System Always Off
+
4
System Always Off
When using the "Custom Output" for "AND" logic
only, switches 1-4 must be programmed to the
type "Always Off" and any of the unused "AND"
switches must be programmed to the type
"Always On".
[3-A]
Custom Output
8
7
custom
AND
5
System Always Off
6
System Always Off
7
System Always Off
8
System Always Off
AND
5
Ward A Set
6
Time Switch 1 On
7
System Always On
8
System Always On

Custom Output - Example 3

This example shows how to use both the "AND" and "OR"
functions so that the "Custom Output" activates when
ward A is set and time switch 1 is active or when the
courtesy light output is active. The table below shows
how each switch is programmed to achieve this.
OR
1
System Courtesy Light
2
System Always Off
3
System Always Off
+
4
System Always Off
When using the "Custom Output" for "AND" and
"OR" logic, any of the unused "OR" switches must
be programmed to the type "Always Off" and
any of the unused "AND" switches (5-8) must be
programmed to the type "Always On".
Engineers Menu 3
AND
5
Ward A Set
6
Time Switch 1 On
7
System Always On
8
System Always On