Engineer's Menu 1

Setting Modes

Each ward A to P can be programmed to set by one of
the following modes:
Final Exit
The ward will set when the "Final Exit" circuit is activated
and after the "Settle Time" has expired.
Exit Terminator
The ward will set when the "Final Exit" circuit is activated,
the "Exit Terminator" button is pressed and after the
"Settle Time" has expired.
Timed Exit
The ward will set when the "Exit Time" has expired or if the
"Exit terminator" button is pressed.
Instant
The ward will set instantly.
Deferred
As Timed Exit, however, if any circuits are activated
during the exit procedure the exit timer is restarted.
6
Engineers menu 1
Setting modes
Setting mode for
Ward A Timed Ext
A C
/
through the Wards
Setting mode for
Ward A Timed ext
1
2
3
4
5
Setting Modes Flowchart
44
[1-6]
[
Setting Mode
to Scroll
= Final ext
= Exit term
= Timed ext
= Instant
= Deferred
[

Do System Print

The system print option is broken down into sections so
that the engineer may print only the relevant details. The
sections are as follows:
Custom Text
Prints the details of "Reset Message", "Location Text",
"Printer Header", "Remote reset Message", "Printer
Prefix", Banner Message", Part Set Banner", "Aux Tamper
1", "Aux Tamper 2" and "Modem String".
Modem Data
Prints the details of "Call back No.1", "Call back No.2",
"Call back No.3", "Modem Site No" and "Modem
Password"
User codes
Prints the "User Number", "User Name", "User Type", "User
Wards", User Auto Sets" and "User Auto Unsets" for each
defined user.
Configuration
Prints the details of all "Configuration Options".
Outputs
Prints the details of "Panel Outputs", "Digicom Outputs",
"D ig i c om C ha nne l s" , " Cu st o m Ou tp ut s" an d
"Node/Rem Outputs"
Setting Modes
Prints the details of "Setting Modes" for wards A to P.
System Timers
Prints the details of all "System Timers" and "System
Options".
Time Switches
Prints the details of "Time Switch 1", "Time Switch 2" and
"Time Switch 3".
Code Locks
Prints the details of "Code lock Group 1", "Code lock
Group 2" and "Code lock Group 1"
Auto-set times
Prints the details of "Auto-set Timer 1", "Auto-set Timer 2"
and "Auto-set Timer 3".
Custom Circuits
Prints the details of the eight "Custom Circuits".
Circuits
Prints the network number, circuit number, circuit status,
set circuit type, unset circuit type, circuit attributes, ward
assignment and circuit resistance for each defined
detection circuit.
Equipment Wards
Prints the ward assignment for all equipment.
Net Equipment
Prints the ward assignment nodes and remote keypads.
Part set groups
Prints the ward assignment and text of the ten part set
groups.