Installing An Xnode; Ts900 Node; Installing A Ts900 Node - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

System Installation

Installing an XNode

1.
Separate the cover and base by using a
screwdriver to push 2 of the clips (left or right) inward
from the base indents, then lift the cover clear.
2.
If the XNode is being fitted inside the control panel
you may remove the XNode PCB from its base and
secure it to the base of the control panel using self
adhesive feet. If required, the tamper switch can be
disabled by fitting the jumper link across JP5, see
Figure 14.
3.
If the XNode is being fitted outside the control
panel, hold the base in position and mark the four
securing holes. Drill and plug the wall as required,
then pass all cables into the base via the cable
entry points as appropriate. Secure the base to the
wall using the appropriate fixing screws.
4.
Connect the network data cables to the
appropriate terminals.
5.
If required, connect the remote keypad network
cables to the appropriate terminals.
6.
If required, connect the extension loudspeaker to
the appropriate terminals. The volume of the
speaker is controlled by the speaker volume
control, see Figure 14.
7.
Set the I/D selector jumper link to the required
position, see the table below, ensuring no two
XNodes on the same network have the same I/D.
8.
Set the "Remote Zone Enable" switch on the XNode
to enable or disable the zones in the remote
keypads as required.
9.
Set JP4 to the TS2500 position.
10.
Finally clip the XNode cover onto the base being
careful not to trap any cables or to obstruct the
tamper switch.
22

TS900 Node

The TS900 Node allows the facility to add an extra eight
pro gr a m m ab l e d e te c t i on c i r c ui t s a nd t w o
programmable outputs. Up to five can be connected
+
to any one network.
TS900 Nodes and XNodes cannot be connected
on the same network.

Installing a TS900 Node

1.
Separate the cover and base of the Node by using
a screwdriver to push 2 of the clips (left or right)
inward from the base indents, then lift the cover
clear.
2.
If the Node is being fitted inside the control panel
you may remove the Node PCB from its base and
secure it to base of the control panel using self
adhesive feet. If required, the tamper switch can be
disabled by fitting the jumper link across JP2, see
Figure 15.
3.
If the Node is being fitted outside the control panel,
hold the base in position and mark the four securing
holes. Drill and plug the wall as required, then pass
all cables into the base via the cable entry points as
appropriate. Secure the base to the wall using the
appropriate fixing screws.
4.
Connect the network data cables to the
appropriate terminals.
5.
Set the I/D selector jumper link to the required
position, see the table below, ensuring no two
nodes, remote keypads or LEC's on the same
network have the same I/D.
6.
Finally clip the Node cover onto the base being
careful not to trap any cables or to obstruct the
tamper switch.
TS2500 Installation Manual

Advertisement

Table of Contents
loading

Table of Contents