Engineers Menu 4

Equipment Wards

This option allows the engineer to assign the following
options to wards.

Panel tamper

The control panel lid tamper can be assigned to any
combinations of wards, this will ensure the correct
tamper response from a lid tamper alarm.

Bell Box Tamper

The bell box tamper can be assigned to any
combination of wards, this will ensure that tamper
alarms from external bell have the correct response.

Aux 1 Tamper

Auxiliary tamper 1 can be assigned to any combination
of wards, this will ensure that tamper alarms from this
input have the correct response.

Aux 2 Tamper

Auxiliary tamper 2 can be assigned to any combination
of wards, this will ensure that tamper alarms from this
input have the correct response.

Phone Line Fault

The phone line fault input can be assigned to any
combination of wards. When a phone line fault occurs
the system will respond as follows:
(a)
All remote keypads will display "PHONE LINE FAULT".
(b)
All internal sounders assigned to the same wards
as the "Phone Line Fault" will generate a chime
tone every minute on the minute and after the line
fault delay timer has expired.
(c)
If "Can Set With L.F" is enabled (see configuration)
users assigned to the same wards as the "Phone
Line Fault" can set their wards but will be asked to
confirm that they are setting with a phone line fault
present.
(d)
If "No Set With L.F" is enabled (see configuration)
users assigned to the same wards as the "Phone
Line Fault" cannot set their wards until the phone
line fault is cleared.

Mains Power Off

The mains power off condition can be assigned to any
combinations of wards. When the loss of mains power
occurs the system will respond as follows:
(a)
All remote keypads display "AC OFF".
(b)
All internal sounders assigned to the same wards
as the "Mains Power Off" will generate a chime
tone every minute on the minute and after the
mains off delay timer has expired.
(c)
If "Can Set-AC Off" is enabled (see configuration)
users assigned to the same wards as the "Mains
Power Off" can set their wards.
80
[4-3]
(d)
If "No Set-AC Off" is enabled (see configuration)
users assigned to the same wards as the "Mains
Power Off" cannot set their wards until the mains
power is restored.

Payment Timer

The payment timer can be assigned to any
combination of wards, when the payment timer expires
the selected wards will then be locked into engineer
reset/remote reset.

Alarms Engineer Reset

Alarms can be assigned as engineer or user reset for
each ward. If a ward is assigned as engineer reset, the
ward can only be reset by the engineer or remote reset
(if remote reset is enabled for that ward). If a ward is not
assigned as engineer reset it becomes user reset and
can be reset by any user that has access for that ward.

Tamper Engineer Reset

Daytime tamper alarms can be assigned as engineer
or user reset for each ward. If a ward is assigned as
engineer reset, a daytime tamper alarm can only be
reset by the engineer or remote reset (if remote reset is
enabled for that ward). If a ward is not assigned as
engineer reset it becomes user reset and can reset by
any user that has access for that ward.

Remote Reset

Remote reset can be enabled or disabled for each
ward. If a ward has remote reset enabled users have
access to the remote reset feature. If a ward does not
have remote reset enabled, only the engineer can
reset after alarm.

Panel Speaker

The control panel speaker can be assigned to any
combination of wards, this will ensure that the sounders
only operate when the relevant ward(s) are in alarm,
entry & exit etc.

Relearn Required

When the system hardware configuration changes the
system requires a relearn. This option allows you to select
which wards require a relearn before the ward can be
set.

Re-arms applies to

The rearm facility can be applied to any combination of
wards. If rearm is applied to a ward the ward will rearm
according to the "Number of rearms'" specified in the
"System Options", see page 45. If rearm is not applied to
a ward, the ward will not auto rearm after an alarm, i.e.,
one activation of the bell.