Connecting a Printer

The TS2500 supports two type of printers, the CPA6
printer (no longer available) and any standard RS232
printer. When using an RS232 printer a DCI/MPA printer
adaptor will be required. Menvier Security supply a
DATAC printer kit which consists of a portable RS232
printer, charger unit and DCI/MPA adaptor.

Using the CPA6 Printer

1.
Plug the CPA6 printer directly on to the PRINTER plug
(JP1) on the main control panel PCB.
2.
The printer will printout a header, when finished the
system program details and event log can be
printed.
3.
When finished unplug the printer. If the printer is left
connected and the on-line printer option is
enabled (see "Configuration" on page 46) events
will be printed as and when they occur.

Using the DATAC / RS232 Printer

1.
Plug the DCI/MPA on to the PRINTER plug (JP1) on the
main control panel PCB.
2.
Plug the other end of the DCI/MPA into the DATAC or
RS232 printer.
3.
In order for the printer to work correctly ensure the
printer is set to the following:
Baud rate
=4800
Parity
= None
Start bits
= 1
Stop bits
= 2
Data bits
= 8
DTR
= Normal
4.
When set-up correctly the system program details
and event log can be printed.
5.
When finished unplug the MPA/DCI. If the printer is
left connected and the on-line printer option is
enabled (see "Configuration" on page 46) events
will be printed as and when they occur.
PL2
1 2 3 4
5 6 7 8
1k Resistors
LED's
Connect to JP1
PRINTER
CPA6 Printer
RS232 Data
MPA
or DCI
Connect to JP1
PRINTER
DATAC or RS232 printer
Figure 28. Printer Connections

Programmable Outputs

The TS2500 system has many programmable outputs
which can be used to drive relays, LED's etc. Each
output can be programmed for a different function,
see "Programmable Output Types" on pages 35 - 39.

Control Panel Outputs

The control panel has four programmable outputs:
[1]
Set of voltage free change-over contacts
rated at 1 Amp.
[-2-]
Switched -ve output rated at 500mA.
[+3]
Switched +ve output rated at 500mA.
[+4]
Switched +ve output rated at 500mA.

Node Outputs

Each XNode and TS900 Node has two programmable
outputs:
[+A]
Switched +ve output rated at 100mA.
[-B ]
Switched -ve output rated at 100mA.
Remote Keypads & TS700.LECs
Each remote keypad and TS700 LEC has one
programmable output:
[O/P]
Switched -ve output rated at 100mA.