Engineer's Menu 2
Event
CODE TAMPER
Keypad locked out for 5 minutes due to invalid entry of passcode
COMMS FAILED
Plug-on digicom failed to communicate with ARC
COMMS SUCCESSFUL Plug-on digicom communicated successfully with the ARC
DATE CHANGED
System date changed
DEFAULT USER ###
User 001 defaulted to 5678
DEFERRED SET:-
Deferred set on wards:- A - P
DIGI-COM FITTED
Plug-on digicom fitted
DIGI/MODEM LOST
Plug-on digicom or modem removed
DIGI/MODEM RESET
Plug-on digi-modem reset
DURESS CODE ###
Duress alarm from user number ###
ENGINEER ARRIVES
Engineer is logged on the system
ENGINEER DEPARTS
Engineer is logged off the system
ENTRY ####
Entry mode started from circuit number ####
ENTRY TIME-OUT:-
Entry mode timed out for wards:- A - P
ENTRY WARDS:-
Entry on wards:- A - P
EXIT CANCELLED:-
Exit mode cancelled for wards:- A - P
EXIT STARTED:-
Exit mode started for wards:- A - P
FACTORY RESTART
Factory default loaded
FIRE ALARM ####
Fire alarm from circuit number ####
FIRE WARDS:-
Fire alarm on wards:- A - P
FIRST KNOCK #### First activation of circuit number #### (circuit with Double-Knock attribute)
From Remote #,## Quick set perform from remote keypad (# = Network, ## =device No)
Hi Security SET:
Wards A - P set using "High Security" feature
LEC #,## TAMPER
Network #, LEC number ## lid tamper alarm
LINE RESTORE
Telephone line restored to healthy
LINK ESTABLISHED
Remote link via PC established
MAINS POWER OFF
Mains power removed from control panel
MAINS POWER ON
Mains power applied to control panel
MENU TIMEOUT ### User number ### entered their passcode and did not selected any functions
MODEM FITTED
Plug-on digi-modem fitted
MODEM LOCK-OUT
Modem locked-out (4 failed attempts made via Lineload)
NODE ### R# ADD Remote keypad added to XNode
NODE ### R# LOST Remote keypad removed from XNode
NODE ### R# TAMP Remote keypad lid tamper from remote on XNode
NODE #,## FUSE
TS900 Node fuse failed
NODE #,## TAMPER TS900 Node lid tamper
NODE SHUNT #### Circuits shunted on a Node
ON-LINE ENDED
Remote service call ended (PC and Lineload)
ON-LINE TO No.#
On-line to remote PC
ON-SITE RESTART
On-site restart
PA ALARM ####
PA Alarm from circuit number ####
P.A CODE ###
PA code from user number ###
PA WARDS:-
PA alarm on wards:- A - P
PANEL LID TAMPER
Control panel lid tamper
PASSCODE ###
User number ### entered their passcode
PAYMENT EXPIRED
System payment timer has expired
PC CONNECTED
PC connected to control panel (PCI/DCI)
PC DISCONNECTED
PC disconnected from control panel (PCI/DCI)