Modem Password; Modem Site No; Program Digicom - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineers Menu 3
1
[ENT] to edit :-
Call back no.1
[ENT] to edit :-
2
Call back no.2
[ENT] to edit :-
3
Call back no.3
0181 12345678
|all No.1 Office
Cursor
Enter Tel No.
Modem Call Back Numbers Flowchart

Modem Password

This option allows the modem password to be
programmed. The "Modem Password" can be up to 16
character long and provides a means of security for
remote communications. When using the "Lineload"
software the "Modem Password" in the site profile must
match the "Modem Password" that is stored in the
control panel.
4
[ENT] to edit :-
Modem password
1234
|Modem password
Cursor
Enter password
(max. 16 characters).
Modem Password Flowchart

Modem Site No.

This option allows the Modem site number to be
programmed. The "Modem Site No." is a 4 digit number
that is used as a site reference. When using the
"Lineload" software the "Site Reference" number in the
site profile must match the "Modem Site No." that is
stored in the control panel.
74
[ to edit
Tel No.
[
[ to edit
Password
[
5
[ENT] to edit :-
Modem site no.
2500
|Modem site no.
Cursor
Enter site No
(max. 4 characters).
Modem Site No. Flowchart

Program Digicom

This option allows the plug-on digicoms DC54, DC58
+
and DC58M to be programmed via the control panel.
When prompted to "press the [0] key to end
programming", it will take approximately 25 - 30
seconds to download the new data to the
+
digicom.
When using the control panel to program a
DC54, the program options that are not
applicable can be ignored, e.g. telephone
number 3 and channels 5 - 8 are not used by the
D C5 4 an d t h e re f o re d o n ot r e qu i re
programming.
TS2500 Installation Manual