Engineer's Menu 1
21
Phone Line Fault
Activates when a line fault is detected,
deactivates when the telephone line is restored.
22
Mains Power Off
Activates when the mains power is removed from
the control panel, deactivates when the mains
power is restored.
23
Exit / Entry
Activates when any ward is in entry or exit mode.
24
Test CCTS Failed
Activates when any circuit fails test, deactivates
when reset by the engineer.
25
1st Knock
Activates when any double knock circuit activates
for the first time, deactivates when the circuit is
activated for the second time or when the system
is reset.
26
Digi Failed
Activates for 5 seconds when the digicom fails to
communicate (plug-on only).
27
Digi Successful
Activates for 5 seconds when the digicom
communicates successfully (plug-on only).
28
Digi Active
Activates when the digicom is activated,
deactivates when the digicom has finished
communicating (plug-on only).
29
2nd entry only
Activates when any ward starts the second entry
timer, deactivates when the second entry time
expires.
30
Entry Only
Activates when any ward starts its entry mode,
deactivates when the ward is unset.
31
Exit Only
Activates when any ward starts its exit mode,
deactivates when the ward is set.
32
Custom o/p 1 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
33
Custom o/p 2 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
34
Custom o/p 3 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
35
Custom o/p 4 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
36
36
Custom o/p 5 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
37
Custom o/p 6 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
38
Custom o/p 7 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
39
Custom o/p 8 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on page
71.
40
Time Switch 1 On
This output is controlled by the settings of "Time
Switch 1" , see "Time Switches" on page 62.
41
Time Switch 2 On
This output is controlled by the settings of "Time
Switch 2" , see "Time Switches" on page 62.
42
Time Switch 3 On
This output is controlled by the settings of "Time
Switch 3" , see "Time Switches" on page 62.
43
Access Code
If configuration option 29 is set to "Access code
only" this output will only activate when an "Access"
type passcode is entered and will remain active
for the duration of the "Access Code Time". If
configuration option 29 is set to "Access all codes"
this output will activate when any valid passcode is
entered and will remain active for the duration of
the "Access Code Time".
44
Payment Required
Activates when the "Payment Time" has expired,
deactivates when engineer resets the system.
45
Battery Test On
Activates during the battery test and for the
duration of the "Battery Test" duration.
46
Rem Service Call
Activates when the system is on-line with a remote
PC and the Lineload software.
47
System Full Set
Activates when all defined wards are set,
deactivates when any ward is unset.
48
24hr Omit Active
Activates when the 24Hr omit group is omitted,
deactivates when the 24Hr group is reinstated.
49
PC Output 1 On
This output is controlled by a PC with Lineload
software.
TS2500 Installation Manual