Wiring A Loudspeaker To An Xnode; Wiring An Output Module To An Xnode; Programmable Outputs On The Xnode; Ts900 Node Wiring - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

System Design
XNode
In
A
From
B
Remote Keypad Network
control
F
A
panel
G
A
Remote
B
I/D=1
Keypad
C
D
E
A
Remote
B
Keypad
C
I/D=2
D
E
A
Remote
B
Keypad
I/D=3
C
D
E
A
Remote
B
Keypad
I/D=4
C
D
E
Fiigure 5. Wiring Remote Keypads to an XNode

Wiring a Loudspeaker to an XNode

The XNode has set of terminals for connecting up to two
16Ω extension loudspeakers. It is recommended that a
remote power supply is connected to the XNode to
provide the additional power for the loudspeaker.

Wiring an Output Module to an XNode

The XNode has a connector for a CPA6 Output Module,
this can be used to provide eight switched -ve outputs
to drive LED's, relays etc. The outputs will mimic the
operation of the detection circuits, i.e. circuit [A] active
= output 1 active, circuit [A] healthy = output 1 inactive.

Programmable Outputs on the XNode

The XNode has two programmable outputs, each rated
at 100mA, output [A+] is a switched +ve output and
output [B-] is a switched -ve. The outputs can be used to
drive sounders or relays etc.
10
Out
G
F
B
B
C
D E
A
XNode
6 Core
Alarm Cable
Power for
+12V
0V
detectors
Spare core used to double
up "B" to reduce voltage drop.
Power for
+12V
0V
detectors
Power for
+12V
detectors
0V
Power for
+12V
0V
detectors

TS900 Node Wiring

TS900 Nodes require a 4 core cable for interconnection,
and up to 5 may be connected in a "daisy-chain" or
"star" configuration to any one network. The distance
between each Node must not exceed 100 metres and
To
the total distance to last Node must not exceed 500
next
metres. Power for detectors is provided by the Aux. +/-
terminals.
The TS900 Node has two programmable outputs, each
rated at 100mA, output [A+] is a switched +ve output
and output [B-] is a switched -ve. The outputs can be
+
used to drive sounders or relays etc.
No two devices should have the same address
+
(I/D).
+
The maximum number of devices is five.
TS900 Nodes and XNodes cannot be connected
on the same network.

Wiring Nodes and Remote Keypads

The TS900 Node and remote keypads can be
connected on the same network. The network must be
wired in 6-core cable to allow the remote keypad
+
internal sounders to operate.
No two devices should have the same address
+
(I/D).
This method of connection is designed for
networks 1 and 2. Although it can be used on
other networks, the "D" connection for the
remote keypads will have to be taken from
+
networks 1 or 2.
The sounder on the remote keypads will follow
+
the control panel sounder.
Remote keypads cannot be multi-tasked
between each other on the same network when
+
using this method of connection.
The maximum number of devices is five.
TS2500 Installation Manual

Advertisement

Table of Contents
loading