Configuration - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineer's Menu 1

Configuration

There are 35 configuration options as follows:
00
Bell Is an SAB (Default)
The control panel bell output applies 0V when
active.
Bell is an SCB
The control panel bell output removes 0V when
active.
01
View alms P.set (Default)
When the system is part set and alarm occurs in a
set ward the alarm information is displayed on all
remote keypads immediately.
View alms unset
When the system is part set and alarm occurs in a
set ward the alarm information is only displayed
when the ward that the alarm occurred in is unset.
02
Duress Disabled (Default)
When entering a passcode with the first two digits
reversed a duress alarm will NOT be generated.
Duress Enabled
When entering a passcode with the first two digits
reversed a duress alarm will be generated.
03
Engr Authorised (Default)
When using Menvier Lineload software data in the
control panel can be overwritten without the users
knowledge.
User Authorised
When using Menvier Lineload software data in the
control panel can only be overwritten with
authorsation by the user.
04
On-Line Enabled (Default)
When using Menvier Lineload software the On-Line
Keypad feature is enabled.
On-Line Disabled
When using Menvier Lineload software the On-Line
Keypad feature is disabled.
05
Lo-sec Engineer (Default)
The engineer can access the engineers
programming menus by entering his engineer's
passcode.
Hi-sec Engineer
The engineer can only access the engineers
programming menus after entering his engineer's
passcode and obtaining a "Remote Reset" code.
06
Normal answer (Default)
When using a DC58M digi-modem the modem
will answer the call after a pre-programmed
number of rings, see "System Options" on page
45.
Timed answer
When using the DC58M digi-modem the
digi-modem will used the "answer ring timer", see
"System Timer" on page 45.
46
[1-9]
07
Unset ward first (Default)
When the system is part set and a passcode is
entered the "0=UNSET WARDS" option will be
displayed first.
Set ward first
When the system is part set and a passcode is
entered the "0=SET WARDS" option will be
displayed first.
08
Can set with L.F (Default)
The selected wards can be set with a telephone
line fault, however the user will be asked to confirm
this at the time of setting. Line fault can be
assigned to any ward , see "Equipment Wards" on
page 80.
No set with L.F
The selected wards cannot be set with a
telephone line fault.
09
Can set - AC off (Default)
The selected wards can be set with no mains
power. Mains power off can be assigned to any
ward , see "Equipment Wards" on page 80.
No set - AC off
The selected wards cannot be set when the mains
power is off.
10
Quiet chimes (Default)
The level of the chime tones is determined by the
volume control of the device driving the
loudspeaker. If the device is a XNode the volume
level set by the volume control pot on the XNode
PCB. If the device is the control panel the volume
level is set via the "Set Volume Level" option, see
"Set Volume Level" on page 83.
Loud chimes
The level of the chime tones is always full volume.
11
O/P 1 normal (Default)
Panel output 1 (Relay) is normally de-energised.
O/P 1 inverted
Panel output 1 (Relay) is normally energised.
12
Digi normal (Default)
The eight digicom outputs on the control panel
switch from +12V to 0V when active (+ve
removed).
Digi inverted
The eight digicom outputs on the control panel
switch from 0V to +12V when active (+ve
applied).
13
4 digit codes (Default)
All system passcodes are 4 digits.
6 digit codes
All system passcodes are 6 digits. When using 6
digit passcode the last 2 digits of the passcode
are the user number, e.g. the engineer's
passcode is 123400 and the master user's
passcode is 567801.
TS2500 Installation Manual