TS2500 Installation Manual
100 metres
Control Panel
In
A
B
4 Core
F
G
Data
Network
100 metres
Control Panel
In
A
B
C/F
E/G
D
Networks
Terminal strip
1 or 2

Remote Keypads and TS700.LECs

Up to 5 remote keypads or TS700.LECs can be
connected on any one network. The devices may be
wired in a "daisy-chain" or "star" configuration. When
using remote keypads the network must be wired in
6-core cable. If all devices on the network are
TS700.LECs the network can be wired in 4-core as the
+
"D" connection is not required.
No two devices should have the same address
+
(I/D).
This method of connection is designed for
networks 1 and 2. Although it can be used on
other networks, the "D" connection for the
remote keypads will have to be taken from
+
networks 1 or 2.
The sounder on the remote keypads will follow
+
the control panel sounder.
Remote keypads cannot be multi-tasked
between each other on the same network when
using this method of connection.
100 metres
I/D=1
I/D=2
TS900
TS900
Node
Node
In
Out
A
A
A
A
B
B
B
B
4 Core
F
F
F
F
G
G
G
G
TS900 Node Connections
100 metres
I/D=1
I/D=3
TS900
TS900
Node
Node
Out
In
A
A
A
A
B
B
B
B
F
F
F
F
G
G
G
G
I/D=2
Remote Keypad
A
B
C
D
E
100 metres
TS900 Nodes and Remotes Connected on the same Network
Figure 6. TS900 Node Wiring Options
500 meters (Max.)
100 metres
I/D=3
TS900
Node
Out
In
Out
A
A
B
B
4 Core
F
F
G
G
100 metres
100 metres
I/D=5
TS900
Node
Out
In
Out
A
A
B
B
F
F
G
G
100 metres
100 metres
100 metres
I/D=4
TS900
Node
In
Out
A
A
B
B
4 Core
4 Core
F
F
G
G
I/D=4
Remote Keypad
A
B
C
D
E
System Design
I/D=5
TS900
Node
In
Out
A
A
B
B
F
F
G
G
11