Log Search Keys; Shunt Groups; Operation - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineers Menu 4

Log Search Keys

This option allows the engineer to configure the nine log
search keys. When viewing the event log you would
normally use the [A] and [C] keys to scroll backwards
and forwards through the event log. The log search keys
allow you to scroll backwards through the log, but will
only display events that meet the search key criteria.
Each search key can have up to 5 search events
assigned to it.
For example, log search key [1] could be set-up to
search for alarms, set wards and unset wards. When
viewing the log and pressing [1] the display would show
the next event that met the search key criteria, i.e. it
would display the next logged alarm, set or unset wards.
If you only want to search for a single event type, then
assign all 5 events as the same type. The table below
shows the default log search key settings:
Key Event 1
Event 2
1
ALARM
ALARM
24hr
24hr
2
ALARM
ALARM
FIRE
FIRE
3
ALARM
ALARM
4
PA ALARM PA ALARM PA ALARM PA ALARM PA ALARM
5
TAMPER
TAMPER
6
ENTRY
ENTRY
PASS
PASS
7
CODE
CODE
SET
SET
8
WARDS
WARDS
UNSET
UNSET
9
WARDS
WARDS
Engineers menu 4
5
Log search keys
Key 1,Event 1 :-
ALARM XXXX
1 8
-
A C
/
Select new event
ALARM XXXX
A C
event types
[
Key 1,Event 1:-
ABORT ON WARDS:-
Log Search Keys Flowchart
82
[4-5]
Event 3
Event 4
Event 5
ALARM
ALARM
ALARM
24hr
24hr
24hr
ALARM
ALARM
ALARM
FIRE
FIRE
FIRE
ALARM
ALARM
ALARM
TAMPER
TAMPER
TAMPER
ENTRY
ENTRY
ENTRY
PASS
PASS
PASS
CODE
CODE
CODE
SET
SET
SET
WARDS
WARDS
WARDS
UNSET
UNSET
UNSET
WARDS
WARDS
WARDS
[
= search Key
to scroll event No.
[
to edit
/
to scroll
to accept

Shunt Groups

The TS2500 alarm system has 50 shunt groups each
group can have up to 4 circuits assigned to it. Each
circuit must have the "Shuntable" attribute assigned in
order for it to be shunted. Each group can then be
allocated to a user passcode (type "Shunt").

Operation

When a shunt passcode is entered the selected group
of circuits are shunted (isolated), this is confirmed by the
remote keypads showing "Your circuits are now
shunted". When the shunt passcode is re-entered, the
selected group of circuits are reinstated and the remote
keypad shows "Your circuit are reinstated".
If the system configuration is programmed as "Unshunt,
no exit", the shunted circuits are reinstated as soon as
the passcode is entered. If the system configuration is
programmed as "Unshunt & exit", the exit procedure is
started when the passcode is entered and the shunted
circuits are reinstated on completion of the exit
procedure.
Engineers menu 4
6
Shunt groups
Group 00<
0001 0001 0001
Enter group No.
[
Group 02
0001 0001 0001
Enter circuit No. then
to move to next circuit
Group 02
2003 2004>2009
[ to accept
Shunt Groups Flowchart
TS2500 Installation Manual
[4-6]
[
0001
to edit
>2002
[
2002

Advertisement

Table of Contents
loading