Dc54/Dc58 Plug-On Digicoms; Dc58M Plug-On Digi-Modem; Output Modules; Control Panel Connections - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

System Installation
CONTROL
PANEL
8
7
6
Program
As:-
5
Open (60)
4
Alarm (05)
3
PA (06)
2
Fire (07)
1
+DC POWER
LINE FLT
REM RESET
AUX 0V
Figure 24. 3GSTU RedCARE Connections

DC54/DC58 Plug-on Digicoms

A plug-on digital communicator DC54 or DC58 can be
fitted inside the control panel to allow alarm status
information to be transferred to a dedicated Alarm
Receiving Centre. The unit should be fitted in
accordance with the installation instructions supplied
with it and connected to the control panel plug
DIGI-MODEM (JP7) using the lead provided with the unit.
The NVM within the digicom can be programmed via
the control panel, see "Digi/Modem options" on page
Connect to JP7
DIGI-MODEM
Telephone cable
(Type 1/0.5mm CW1308)
B.T. master jack ( Type NTE5
user accessible connections )
Figure 25. DC54/DC58 Connections
73.
28
3GSTU
Channel Inputs are
Programmed as
Positive Removed
Plug-on digicom / digi-modem
A
B
BC
6
White / Blue ring
5
4
Blue / White ring
3
2
Orange / White ring
1

DC58M Plug-on Digi-modem

A plug-on digi-modem DC58M can be fitted inside the
control panel to allow remote interrogation and
programming via a personal computer (PC). It will also
function as a standard digicom (if required). The unit
should be fitted in accordance with the installation
instructions supplied with it and connected to the
control panel plug DIGI-MODEM using the lead
provided with the DC58M. The NVM within the
digi-modem can be programmed via the control
panel, see "Digi/Modem options" on page 73. The
modem data is also programmed via the control
panel.
Telephone
Network
V21.
Modem
Figure 26. DC58M Digi-modem Schematic

Output Modules

The Output Module provides eight switched -ve outputs
each rated at 100mA. They can be used to drive LED's or
relays etc. Each module is supplied with an interface
lead which allows it to be connected to the control
panel or XNode. Output modules are normally fitted
inside the equipment they are controlling and can be
positioned up to 100 metres away.

Control Panel Connections

When connected to the control panel the output
modules can be programmed to give ward status
indications and/or circuit mimic/alarm indications.

XNode Connections

When connected to the XNode, the output module will
provide circuit mimic indications for the eight detection
circuits of the XNode.
TS2500 Installation Manual
TS2500 Control
Panel
DC58M
Alarm Receiving
Centre