Time Switches; Part Set Groups - Menvier Security TS2500 Installation & Programming Manual

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineers Menu 3
1
= On-time 1
2
= On-time 2
3
= On-time 3
Time switch 1
On-time 1 00:00
Enter On-time
[

Time Switches

The TS2500 has three programmable time switches.
Each time switch can be programmed with up to three
separate on/off times and made to operate on any day
of the week. The time switches can be assigned to
outputs which in turn can be used to control internal or
external lighting via a relay etc.
62
Engineers menu 3
1
Time switches
[
Time switch 1
Select option :-
A
= Time switch 1
B
= Time switch 2
C
= Time switch 3
4
= Off-time 1
5
= Off-time 2
6
= Off-time 3
Time swicth 1
Off-time 1 00:00
Enter Off-time
1
[
Time Switches Flowchart
[3-1]

Part Set Groups

This option allows the engineer to define up to 10
part-set groups. Each group can be programmed so
that it sets any combination of wards. For example "PART
SET GROUP 1" could be allocated wards A and C,
whereas "PART SET GROUP 2" could be allocated wards
A and B.
7
= 1st operates on
0 = Manually switch output
8
= 2nd operates on
9
= 3rd operates on
1 Operates on :-
> SunMo..........
Enter days of operation
=Sunday,
7
=Saturday
[
Engineers menu 3
2
Part set groups
PART SET GROUP 0
................
Press
1 0
-
to select part set group
PART SET GROUP 0
*,*,*,*,.,.,.,.
1 8
-
toggle wards.
A C
/
to scroll wards A-H
and wards I-P
Ward Status Key
*
= Ward not selected.
.
= Ward not available.
A-P
= Wards selected.
Part Set Groups Flowchart
TS2500 Installation Manual
Time switch 1
> output is OFF
B
= Toggle ON/OFF
[
[3-2]
[
or
A C
/
[
Wards
[

Advertisement

Table of Contents
loading